² Ác ­º­¶>®üÃöºî¦X«H®§¸ê°T>°ê»Ú¶T©ö>¥~¶T­^»y>[¥»¤åBIG5]2007¦~³Ì·s¤¤°ê®üÃöµ|²vµ|«h¬d¸ßªí
¹q¤uµü¶×­^º~¹ï·ÓP
¤¤°ê®üÃöºî¦X«H®§¸ê°TÊI-®üÃö³qÃö³øÃö«t¸ß/¶i¥X¤f²Î­p¼ÆÕuÃöµ|¬d¸ß
¡¡¡¡P-net,P-netÁ`½u

P-scope,P«¬Åã¥Ü

P.T.C.thermistor,¥¿·Å«×¨t¼Æ¼ö±Ó¹qªý¾¹

p-type oxide gas sensor,P«¬®ñ¤Æª«Éa±Ó¤¸¥ó

P-V-T-t technique,À£¤O-®e¿n-·Å«×-®É¶¡ªk

pack,¥]¸Ë¥ó

package,¥]¸Ë¡F¥]¸Ë¥ó

packaging,¥]¸Ë

packaging standard,¥]¸Ë¼Ð­ã

packed capillary column,¯u¥R¤ò²ÓºÞ¬W

packed column,¶ñ¥R¬W

packed-type solenoid valve,¶ñ®Æ¨ç«¬¹qºÏ»Ö

packet,¥]

packet mode,¥]¤è¦¡

packet sequencing,¥]±Æ§Ç

packet switching,¥]¥æ´«

packing,¥]¸Ë

packing box assembly,¶ñ®Æ¨ç²Õ¥ó

packing machine (liquid chromatographic column),¡]²G¬Û¦âÃЬW¡^¸Ë¶ñÉó

packless solenoid valve,µL¶ñ®Æ¨ç«¬¹qºÏ»Ö

page addressing,­¶­±´M§}

page printer,­¶¦¡¥´¦LÉó

page-at-a-time printer,¤@¦¸¤@­¶¦L¨êÉó¡F­¶¦¡¦L¨êÉó

panel,½L¡F«Ì¡Aµe­±

panel mounting (pressure) gauge,½L¸ËÀ£¤Oªí

panoramic exposure,©P¦V·Ó®g¡F¥þ´º·Ó®g

pantograph,ÁY©ñ»ö

paper based strain gauge,¯È°òÀ³ÅÜ­p

paper chromatography,¯È¦âÃЪk

paper tape,¯È±a

paper tape punch,¯È±aªÅ¤ÕÉó

paper tape reader,¯È±a¾\ŪÉó

paper tape unit,¯È±a³æ¤¸

parachute drogue,º}¬y³Ê

parallax,µø®t

parallel computer,¦}¦æ­pºâÉó

parallel crate controller,¦}¦æÉó½c±±¨î¾¹

parallel highway,¦}¦æ«H®§¤½¸ô

parallel operation,¦}¦æ¾Þ§@¡F¦}Áp¤u§@

parallel output system,¦}¦æ¿é¥X¨î

parallel plate micrometer,¥­ªO´ú·L¾¹

parallel processing,¦}¦æ³B²z

parallel programming,¦}¦æµ{§Ç³]­p

parallel transmission,¦}¦æ¶Ç¿é

paramagnetic oxygen analyzer,¶¶ºÏ¦¡®ñ¤ÀªR¾¹

parameter,°Ñ¼Æ

parametric input,°Ñ¶q¿é¤J

parasitic echo,¤zÊð¤Ï®gªi

parasitic voltage of voltage divider,¤ÀÀ£½c±H¥Í¹qÀ£

parasol radiometer,³Ê¦¡¿ç®g­p

parent-molecule ion,¥À¤À¤lÖäl

parity check,©_°¸®ÕÅç

partial failure,³¡¤À¥¢®Ä

partial immersion,thermometer,§½®û·Å«×­p

partial pressure gauge (PPG)¡A¤ÀÀ£±j­p

partial radiation thermometer,³¡¤À¿ç®g·Å«×­p

partition chromatography,¤À°t¦âÃЪk

partition coefficient,¤À°t¨t¼Æ

partition isothem,¤À°tµ¥·Å½u

part-turn electric actuator,¨¤¦æµ{¹q°Ê°õ¦æÉóÌÛ

Pascal,©¬¡]´µ¥d¡^

pass-line deflection,¶]°¾

passing unregistered gas (PUG),º|°OÉaÊ^

passive remote sensing,³Q°Ê»»·P

passive transducer [sensor],µL·½¶Ç·P¾¹

path,³q¸ô

path frame,³q¸ô´V

path protocol,³q¸ô¨óij

path unit,³q¸ô³æ¤¸

pattern,±´¶Ë¹Ï§Î

pattern coefficient,¹Ï«¬¨t¼Æ

pattern recognition,¼Ò¦¡ÃѧO

peak,®p

peak area,®p­±¿n

peak base,®p©³

peak detector,®p­ÈÀ˪i¾¹

peak distortion,ÃЮp·îÅÜ

peak energy,®p¯à¶q

peak height,®p°ª

peak identification,ÃЮpų§O

peak matching,®p¤Ç°t

peak of noise,¾¸Án°ª«×

peak overlap,ÃЮp­«Å|

peak point,®p³»¡]ÂI¡^

peak separation,®p¶Z

peak shape factor,®p§Î¨t¼Æ

peak sound pressure,®p­ÈÁnÀ£

peak stripping,ÃЮp­éÖÃ

peak temperature,®p·Å«×

peak time,®p­È®É¶¡

peak-to-peak value,®p®p­È

peak-to-peak value of displacement,®p-®p­È¦ì²¾

peak (top) flatness,®p³»¥­ª½«×

peak transmittance,®p­È³z¹L²v

peak value,®p­È

peak value of humidity,Àã«×®p­È

peak value of temperature,·Å«×®p­È

peak voltmeter,®p­È¹qÀ£ªí

peak wavelength,®p­Èªiªø

peak width,®p¼e

peak width at half height,¥b°ª®p¼e

Peltier coefficient,¬Äº¸©«¨t¼Æ

Peltier heat,¬Äº¸©«¼ö

pen,¾¥¤ôµ§

pen recorder,µ§¦¡°O¿ý»ö

pen rising mechanism,©ïµ§ÉóÌÛ

pendulum impact testing machine,Â\Á覡½ÄÀ»¸ÕÅçÉó

pendulum meter,Â\»ö

pendulum striking edge,Â\Áè½ÄÀ»¤M¤b

penetrameter,³z«×­p¡F¹³½è­p

penetrant inspection unit,º¯³z²G²M¬~¾¯

penetrant testing method,º¯³z±´¶Ëªk

penetrants,º¯³z²G

Penning gauge,§N³±Ìå¹qÖóW¡F¼ïÉr³W

percentage of theoretical slope (PTS),¦Ê¤À²z½×±×²v

performance,©Ê¯à

performance characteristics,©Ê¯à¯S©Ê

performance evaluation,©Ê¯à«ü¼Ð

periodic and random deviations(PARD),©P´Á©MÀHÉó°¾®t

periodic damping,©P´Áªý¥§¡F¤íªý¥§

periodic test,©w´Á¸ÕÅç

periodic vibration,©P´Á®¶°Ê

periodic waves marker,©P´Áªi®É¼Ð

peripheral control unit,¥~³ò³]³Æ±±¨î¾¹

peripheral equipment,¥~³ò³]³Æ

peripheral flow-rate,©P½t¬y¶q

peripheral interface adapter(PIA),¥~³ò±µ¤fÓì°t¾¹

peripheral transfer,¥~³ò¶Ç°e

peristaltic multi-channel pump,¦h³q¹Dį°Ê¬¦

permanent flow-rate,±`³]¬y¶q

permanent-magnet-coil instrument,¥ÃºÏ°Ê°é¦¡[ºÏ¹q¨t]»öªí

permanent magnetic lens,¥ÃºÏ³zÃè

permanent-magnet movingcoil galvanometer,¥ÃºÏ°Ê°é¦¡[ºÏ¹q¨t]Àˬy­p[®¶°Ê¤l]

permeability,º¯³z²v

permeability tube,º¯³zºÞ

permeameter,ºÏ¾É­p

permissible cumulative discharge of standard cell,¼Ð­ã¹q¦À¤¹³\²Ö­p©ñ¹q¶q

permissible discharge of standard cell,¼Ð­ã¹q¦À¤¹³\©ñ¹q¶q

persistent wave NMR spectroscope,Ãäæªi®ÖºÏ¦@®¶ªiÃлö

personal error,¤H¬°»~®t

petroleum oil detection buoy system,¥Ûªo±´´ú¯B¼Ð¨t²Î

Ph electrode assembly,PhÎ`¦X¹qÌå

Ph meter,Ph­p

Ph transducer [sensor],Ph¶Ç·P¾¹

Ph value,Ph­È

phase,¬Û

phase analysis,¬Û¦ì¤ÀªR

phase angle,¬Û¨¤

phase angle stabilization,¬Û¨¤Ã­©w

phase contrast,¦ì¬ÛŨ«×

phase controlled circuit breaker,Â_¹q¬Û¦ì±±¨î¾¹

phase datum mark,¬Û¦ì°ò­ã¼Ð°O

phase detection,¬Û¦ìÀË´ú

phase detector,ų¬Û¾¹

phase difference,¬Û¦ì®t

phase difference torque transducer,¬Û¦ì®t¦¡Âà¯x¶Ç·P¾¹

phase displacement,¬Û¦ì®t¡F¨¤»~®t

plase distance meter,¬Û¦ì¦¡´ú¶Z»ö

phase indicator,¬Û¦ì«ü¥Ü¾¹

phase lage,¬Û¦ìº¢¦Z

phase lead,¬Û¦ì¶W«e

phase locus,¬Û­y¸ñ

phase margin,¬Û¦ì¸Î«×

phase measurement,¬Û¦ìªº´ú¶q

phase meter,¬Û¦ìªí

phase modulation (PM),¬Û¦ì½Õ¨î¡F½Õ¬Û

phase of unbalance,¤£¥­¿Å¬Û¦ì

phase plane,¬Û¥­­±

phase plane portrait,¬Û¥­­±¹Ï

phase ratio,¬Û¤ñ²v

phase reference generator,°Ñ¦Ò¬Û¦ìµo¥Í¾¹

phase response,¬Û¦ìÅTÀ³

phase sensitive detector,¬Û±ÓÀ˪i¾¹

phase sequence indicator,¬Û§Ç«ü¥Ü¾¹

phase space,¬ÛªÅ¶¡

phase trajectory,¬Û­y¸ñ

phase transition,¬ÛÅÜ

phase variable,¬ÛÅܶq

phase-continuous FSK,¬Û¦ì³sÄòFSK

phase-crossover frequency,¬Û¦ì¥æ¶VÀW²v

phase-frequency characteristics,¬ÛÀW¯S©Ê

phase-shift ultrasonic flowmeter,¬Û²¾¦¡¶WÁn¬y¶q­p

phon,¤è¡]ÅT«×¯Åªº³æ¦ì¡^

phosphorescence,ÁC¥ú

photo conduction tube,¥ú¾ÉºÞ

photo electron spectroscopy (PES),¥ú¹q¤l¯àÃЪk

photo-electrical coded compass,¥ú¹q½Xù½L

photo-electrostatic display recorder,·P¥úÀR¹qÅã¥Ü°O¿ý»ö

photo ionization,¥ú¹qÖÃ

photo resistor,¥ú±Ó¹qªý¾¹

photo-sensitive recorder,·P¥úÅã¥Ü°O¿ý»ö

photo sensor,¥ú±Ó¤¸¥ó

photo-theodoliti,Äá¼v¸g½n»ö

photoacoustic spectrometry,¥úÁn¥úÃЪk

photoconductive transducer [sensor],¥ú¾É¦¡¶Ç·P¾¹

photoelectric colorimeter,¥ú¹q¤ñ¦âªk

photoelectric comparator,¥ú¹q¤ñ¸û»ö

photoelectric effect,¥ú¹q®ÄÀ³

photoelectric fluxmeter,¥ú¹qºÏ³qªí

photoelectric length meter,¥ú¹q¦¡ªø«×­p

photoelectric position detector,¥ú¹q¦¡¦ì¸mÀË´ú¾¹

photoelectric roll gap measuring instrument,¥ú¹q¦¡¾@Á_´ú¶q»ö

photoelectric tachometer,¥ú¹q¦¡Âà³tªí

photoelectric tachometric transducer,¥ú¹q¦¡Âà³t¶Ç·P¾¹

photoelectric thermometer,¥ú¹q·Å«×­p

photoelectric transmissometer,¥ú¹q³z®g»ö

photoelectric width meter [gauge],¥ú¹q¦¡¼e«×­p

photoelectro magnetic element,¥ú¹qºÏ±Ó¤¸¥ó

photoionization detector (PID),¥úÖäl¤ÆÀË´ú¾¹

photometer,¥ú«×­p

photometric linearity,¥ú«×´ú¶q½u©Ê

photomultiplier,¥ú¹q­¿¼WºÞ

phototheodilite,Äá¼v¸g½n»ö¡F·Ó¬Û¸g½n»ö

phototube,¥ú¹qºÞ

photovoltaic cell,¥ú¹q¦À

photovoltaic transducer [sensor],¥ú¥ñ¦¡¶Ç·P¾¹

physical layer (PL),ª«²z¼h

physical model,ª«²z¼Ò«¬

physical modeling,ª«²z«Ø¼Ò

physical property type transducer [sensor],ª«©Ê«¬¶Ç·P¾¹

physical quantity transducer [sensor],ª«²z¶q¶Ç·P¾¹

physical similarity,ª«²z¬Û¦ü

physical simulation,ª«²z¥é¯u

physical symbol system,ª«²z²Å¸¹¨t²Î

physiological quantity transducer [sensor],¥Í²z¶q¶Ç·P¾¹

picture spectrograph,¹Ï¶HÄáÃлö

piezoelectric acceleration transducer,À£¹q¦¡¥[³t«×¶Ç·P¾¹

piezoelectric effect,À£¹q®ÄÀ³

piezoelectric force transducer,À£¹q¦¡¤O¶Ç·P¾¹

piezoelectric microphone,À£¹q¶ÇÁn¾¹

piezoelectric pressure transducer,À£¹q¦¡À£¤O¶Ç·P¾¹

piezoelectric transducer [sensor],À£¹q¦¡¶Ç·P¾¹¡FÀ£¹q´«¯à¾¹

piezoelectric vibrator,À£¹q®¶°Ê¾¹

piezoelectric vibrometer,À£¹q¦¡®¶°Ê­p

piezometer ring,§¡À£Àô

piezo-resistance effect,À£ªý®ÄÀ³

piezoresistive acceleration transducer,À£ªý¦¡¥[³t«×¶Ç·P¾¹

piezoresistive accelerometer,À£ªý¦¡¥[³t«×­p

piezoresistive effect,À£ªý®ÄÀ³

piezoresistive pressure transducer,À£ªý¦¡À£¤O¶Ç·P¾¹

piezoresistive transducer [sensor],À£ªý¦¡¶Ç·P¾¹

piezoresistive vibrometer,À£ªý¦¡®¶°Ê­p

piggy-back microbiological sampler,Î`­I¦¡·L¥Íª«ªö¶°¾¹

pilot,¥ý¾É»Ö

pilot valve,«ü´§¾¹

pilot balloon theodolite,´ú­·¸g½n»ö

pilot-operated regulator,«ü´§¾¹¾Þ§@«¬¦Û¤O¦¡½Õ¸`»Ö

pilot-operated solenoid valve,¥ý¾É«¬¹qºÏ»Ö

pin-cushion distortion,ªE§Î·îÅÜ¡F¥¿·îÅÜ

pinger,¤ôÁn«H¼Ð

pinion,¶b¾¦½ü

pink noise,¯»¬õ¾¸Án

pipe prover,¼Ð­ãÊ^¿nºÞ¡FºÞ¦¡®Õ­ã¾¹

pipe reducer,ÉÝ®|±µºÞ

Pirani gauge,¹qªý³W¡F¥Ö©Ô¥§³W

Pirani vacuum gauge,¥Ö©Ô¥§¯uªÅ­p

piston,¬¡¶ë

piston actuator,¬¡¶ë°õ¦æÉóÌÛ

piston-cylinder assembly,¬¡¶ë³¡¥ó

piston gauge,¬¡¶ë¦¡À£¤O­p

piston gauge with equilibrium liquid,±a¥­¿Å²G¬W¬¡¶ë¦¡À£¤O­p

piston gauge with re-entrant cylinder column,¤ÏÀ£¬¡¶ë¦¡À£¤O­p

piston prover,¬¡¶ë®Õ­ã¾¹

piston rotation perdurability,¬¡¶ë¤U­°³t«×

piston with weight carrier,±a¦³©³½L¸Ë¸mªº¬¡¶ë

pistonphone,¬¡¶ëµoÁn¾¹

Pitot static tube,¥Ö¦«ÀRÀ£ºÞ

Pitot tube,¥Ö¦«ºÞ

pivot galvanometer,¶b¦y¦¡Àˬy­p

pivot knife-plane,¤äÂI¤M®y

plain glass window,¨¾Å@¥Õ¬Á¼þÆ[¹îµ¡

planar array,¥­­±°}

planar (quad) location,¥­­±©w¦ì

plane bearing,¥­­±¤ä©Ó

plane grating,¥­­±¥ú¬]

plane separation,¥­­±¤ÀÖÃ

plane separation network,¥­­±¤ÀÖùq¸ô

plane table equipment,¥­ªO»ö

plane table thermoconductivity meter,¦æ¬P¾¦½ü´î³t¾¹

planimeter,¨D¿n»ö

plankton bucket,¯B´å¥Íª«ÊI©³ºÞ

plankton counting chamber,¯B´å¥Íª«­p¼Æ®Ø

plankton haul [trawl],¯B´å¥Íª«©ìÊI

plankton net,¯B´å¥Íª«ÊI

plankton pump,¯B´å¥Íª«¬¦

plankton tow net,¯B´å¥Íª«©ìÊI

plankton volume indicator,¯B´å¥Íª«Ê^¿n´ú¶q¾¹

plant environment,¤uÉDÀô¹Ò

plant growth test chamber,´Óª«¥Íªø¸ÕÅç½c

plasma chromatograph-mass spectrometer (PC-MS),µ¥Öäl¦âÃÐ-½èÃÐÁp¥Î»ö

plasma chromatography,µ¥Öäl»k¨èÉó

plastic sampler,¶ì®Æªö¤ô¾¹

plastic window,¶ì®ÆÆ[¹îµ¡

plasticity,¶ì©Ê

plate wave,ªOªi

plate wave technique,ªOªiªk

plateau,¥­¥x¡F©W

Platinum-10% Rhodium/Platinum thermocoupe,¹`ä{10-¹`¼ö¹q°¸

Platinum-13% Rhodium/Platinum thermocouple,¹`ä{13-¹`¼ö¹q°¸

Platinum-30% Rhodium/Platinum-6% Rhodium thermocouple,¹`ä{30-¹`ä{6¼ö¹q°¸

platinum resistance thermometer sensor,¹`¼ö¹qªý

playback apparatus,¦^©ñ»ö

plotter,ø¹ÏÉó¡Fø¹Ï»ö¡F¦a¾_­å­±»ö

plotting tablet,¼Ð¹ÏªO

plug-in unit,´¡¥ó

plug valve,±Û¶ë»Ö

plumb,««ª½¾¹

plunger,°ÊÅKªä

plunger pump,¬W¶ë¬¦

plunger tube,¹jºÏºÞ

plunger viscometer,¬¡¶ë¦¡Ö߫׭p

pluviograph,«B¶q­p

pluvioscope,­°¤ô´ú©w¾¹

pneumatic actuator,Éa°Ê°õ¦æÉóÌÛ

pneumatic bubbling gauge,¸ÉÉa¤ÞÀ£¦¡Åç¼é»ö

pneumatic control,Éa°Ê±±¨î

pneumatic limit operator,Éa°ÊÌå­­¾Þ§@¾¹

pneumatic piston gauge,Éa°Ê¬¡¶ë¦¡À£¤O­p

pneumatic pump,Éa°Ê¬¦

pneumatic rotary actuator,¨¤¦æµ{Éa°Ê°õ¦æÉóÌÛ

pneumatic system,Éa°ÊÀ£¤O¨t²Î

pneumatic thickness meter,Éa°Ê«p«×­p

point drift,ÂIº}

point filament,ÂIÀY¿Oµ·

point location,ÂI©w¦ì

point-to-point connection,ÂI¹ïÂI³s±µ

point-to-point control,ÂI¹ïÂI±±¨î¡FÂI¦ì±±¨î

point-to-point control system,ÂI¨ìÂI±±¨î¨t²Î

point to point resolution,ÂI¤À¿ë¤O

point-to-point transmission,ÂI¹ïÂI¶Ç¿é

pointer,«ü°w¡F«ü¥Ü¦r

pointer adjustment,«ü°w½Õ¾ã¾¹

pointer galvanometer,«ü°w¦¡Àˬy­p

pointer instrument,«ü°w¦¡»öªí

pointer length,«ü°wªø«×

pointer travel,«ü°wÂਤ

points of mean axial fluid velocity,¥­§¡¶b¦V¬yÊ^³t«×ÂI

poise nut,¥­¿Åà®

polar aurora,Ìå¥ú

polar coordinate type potentiometer,Ì姤¼Ð¦¡¹q¦ì®t­p

polar plot,Ìå½u¹Ï

polarimeter,°¾®¶ªí¡F°¾®¶­p

polarimetry,±Û¥úªk

polariscope,°¾®¶»ö

polarity indicator,Ìå©ÊÅTÀ³®É¶¡

polarization voltage,Ì夯¹qÀ£

polarized cartridge capacitance,Ì夯ÌåÀY¹q®e

polarogram,ÌåÃйÏ

polarograph,ÌåÃлö

polarograph quantitative detection limit,ÌåÃлö©w¶qÀË´ú­­

polarographic cell,ÌåÃЦÀ

polarographic maxima,ÌåÃÐÌå¤j

polarography,ÌåÃЪk

pole,ÌåÂI

pole assignment,ÌåÂI°t¸m

pole piece,Ìå¹u

polling,±´¸ß¡F½ü¸ß

pollution,¦Ã¬V

polyamide,»E¡@Ói

polyethylene,»E¤A²m

polypropylent,»E¤þ²m

polytetrafluror-ethylene (teflon),»E¥|¬t¤A²m¡]¯S¬t¶©¡^

polyvinyliden fluoride,»E¬t¤A²m

popular scanning electron microscope,´¶¤Î«¬±½´y¹q¤lÅã·LÃè

popular transmission electron microscope,´¶¤Î«¬³z®g¹q¤lÅã·LÃè

population,Á`Ê^

porcelain insulator,µ´½t²¡²~

porous polymer beads,°ª¤À¤l¦h¤Õ¤p²y

porous-layer open-tubular column;PIOT column,¦h¤Õ¼hªÅ¤ß¬W

port,³q«H¤f¡FºÝ¤f

port guiding,»Ö¤f¾É¦V

portable hardness tester,Äâ±a¦¡µw«×­p

portable multipurpose instrument set,»´«Kºî¦XÆ[´ú»ö

portable X-ray detection apparatus,Äâ±a¦¡X®g½u±´¶ËÉó

portability,¥i²¾´Ó©Ê

portable (measuring) instrument,¥i[«K]Ä⦡¡]´ú¶q¡^»öªí

position,¦ì¸m

position encoder,¦ì¸m½s½X¾¹

position error,¦ì¸m»~®t¡F¥|¨¤»~®t

position error coefficient,¦ì¸m»~®t¨t¼Æ

position feedback,¦ì¸m¤ÏõX

position indicating switch,»Ö¦ì«ü¥Ü¶}Ãö

position limit switch,¦æµ{¶}Ãö

position transducer [sensor],¦ì¸m¶Ç·P¾¹

positioner,©w¦ì¾¹

positive displacement flowmeter,®e¿n¦¡¬y¶q­p

positive feedback,¥¿¤ÏõX

positive knives linear,¥¿¤MÁp½u

positive-negative action,¥¿­t§@¥Î

positive negative three-step action,¥¿­t¤T¦ì§@¥Î

positive pressure,¥¿À£

positive shock response spectrum,¥¿½ÄÀ»ÅTÀ³ÃÐ

positive strain,¥¿À³ÅÜ

positive system,¥¿¨t²Î

positive temperature coefficient thermistor,¥¿·Å«×¨t¼Æ¼ö±Ó¹qªý

post emulsifiable dye penetrant testing method,¦Z¨Å¤Æ©ÊµÛ¦âº¯³z±´¶Ëªk

post emulsifiable fluorescent penetrant testing method,¦Z¨Å¤Æ©Êº·¥úº¯³z±´¶Ëªk

post emulsifiable penetrant,¦Z¨Å¤Æ©Êº¯³z²G

potential evaporation,»]µo²v

potentiometer,¹q¦ì¾¹

potentiometer compass,¹q¦ì¾¹Ã¹½L

potentiometer pressure transducer,¹q¦ì¾¹¦¡À£¤O¶Ç·P¾¹

potentiometer type pressure transducer,¹q¦ì¾¹¦¡À£¤O¶Ç·P¾¹

potentiometric analyzer,¹q¦ì¦¡¤ÀªR¾¹

potentiometric displacement transducer,¹q¦ìºw©w¡]ªk¡^

potentiometric transducer [sensor],¹q¦ì¾¹¦¡¶Ç·P¾¹

potentiometry,¹q¦ìªk

powder-filled enclosure (Ex q¡^¡A¥R¬â¥~´ß(Ex q¡^

powder sample,¯»¥½¼Ë«~

power amplifier,¥\²v©ñ¤j¾¹

power compensation differential scanning calormeter,¥\²v¸ÉÀv®t¥Ü±½´y¶q¼ö»ö

power-compensation differential scanning calorimetry,¥\²v¸ÉÀv«¬®t¥Ü±½´y¶q¼öªk

power factor meter,¥\²v¦]¼Æªí

power source,¥D¹q·½

power spectral density,¥\²vÃбK«×

power supply device,¹q·½¸Ë¸m

power supply frequency,¹q·½ÀW²v

power supply voltage,¹q·½¹qÀ£

power system automation,¹q¤O¨t²Î¦Û°Ê¤Æ

power-fail circuit,¹q·½¬G»Ù¹q¸ô

practical response time,¹ê¥ÎÅTÀ³®É¶¡

practical salinity scale 1978,1978¹ê¥ÎÆQ¼Ð

pre-conditioning time,¹w³B²z®É¶¡

pre-vacuum chamber,¹w©â«Ç

pre-weighing,¹wºÙ¸Ë¸m

preamplifier,«e¸m©ñ¤j¾¹

precipitation gauge,«B¶q¶qµ©

precipitation intensity,­°¤ô±j«×

precise stereoplotter,ºë±K¥ßÊ^´ú¹Ï»ö

precision,ºë±K«×

precision disc grinder,¼Ë«~¿iÁ¡Éó

precision micrometer [microdisplacement] inspection instrument,ºë±K´ú·LÀË©w»ö

precision of measurement,´ú¶qºë±K«×

precision (pressure) gauge,ºë±KÀ£¤Oªí

predictive control,¹w´ú±±¨î

preliminary adjustment,ªì½Õ¡F¹w½Õ¾ã

premix burner,¹w²V¿U¿N¾¹

preparative chromatography,¨î³Æ¦âÃЪk

preparative gas chromatograph,¨î³ÆÉa¬Û¦âÃлö

preparative liquid chromatograph,¨î³Æ²G¬Û¦âÃлö

prepayment meter,¹w¥I¶O¹q«×ªí

press,À£¶ôÉó

pressure,À£¤O¡FÀ£±j

pressure adjusting screw,À£¤O½Õ¸`Á³§ý

pressure altitude formula,ÉaÀ£´ú°ª¤½¦¡

pressure bell,¤ÞÀ£ÄÁ

pressure compensator,À£¤O¸ÉÀv¾¹

pressure constant state,ùÚÀ£ª¬ºA

pressure/depth conversion factor,À£¤O-²`«×Âà´«¨t¼Æ

pressure facility,À£¤O³]³Æ

pressure frequency response of microphone,¶ÇÁn¾¹ÁnÀ£ÀW²vÅTÀ³

pressure gauge,À£¤Oªí

pressure gauge tester,À£¤Oªí®ÕÅç¾¹

(pressure)gauge with back connection,¶b¦VÀ£¤Oªí

(pressure)gauge with bottom connection,®|¦VÀ£¤Oªí

(pressure)gauge with electric contact,¹q±µÂIÀ£¤Oªí

(pressure)gauge with transmission device,¹q»·¶ÇÀ£¤Oªí

pressure gradient correction factor,À£¤O±è«×®Õ¥¿¦]¤l

pressure gradient microphone,À£®t¶ÇÁn¾¹

pressure in the ocean,®ü¬v¤¤ªºÀ£¤O

pressure instrument,À£¤O»öªí

pressure isolating chamber,À£¤O¹jÖîe¾¹

pressure level measuring device,À£¤O²G¦ì´ú¶q¸Ë¸m

pressure loss,À£¤O·l¥¢

pressure measuring set,À£¤O´ú¶q»ö

pressure microphone,À£±j¶ÇÁn¾¹

(pressure) multiplier,­¿À£¾¹

pressure-operated plankton net,À£¤O¶}Ãö¯B´å¥Íª«ÊI

pressure plate anemometer,À£ªO­·³tªí

pressure range,À£¤O­S³ò

pressure ratio,À£¤O¤ñ

pressure recovery,À£¤O«ìÎ`

pressure regulator,´îÀ£¾¹

pressure regulator spring,´îÀ£¾¹¼u®

pressure regulator valve,´îÀ£¾¹·Æ»Ö

pressure regulator valve pin,´îÀ£¾¹»Ö°w

pressure regulator valve spring,´îÀ£¾¹»Ö¼u®

pressure relief plug,ªnÀ£¶ë[ªO]

pressure repeater,À£¤O­«Î`¾¹

pressure seal,À£¤O¹jÖø˸m

pressure sensitivity of microphone,¶ÇÁn¾¹ÁnÀ£ÆF±Ó«×

pressure spectrum level,ÁnÀ£ÃЯÅ

pressure (step-type)controller,À£¤O¡]¦ì¦¡¡^±±¨î¾¹

pressure switch,À£¤O¶}Ãö

pressure tappings [taps],¨úÀ£¤f

pressure test chamber,ÉaÀ£¸ÕÅç½c

pressure tide gauge,À£¤O¦¡Åç¼é»ö

pressure tight case,Éa±K¥~´ß

pressure transducer [sensor],À£¤O¶Ç·P¾¹

pressure transmitter,À£¤OÅܰe¾¹

pressure tube anemometer,À£ºÞ­·³tªí

pressure type wave gauge,À£¤O¦¡´úªi»ö

pressure vessel,À£¤O®e¾¹

pressurized enclosure (Ex p),¥¿À£¥~´ß¡]Ex p¡^

prevacuum,«e¯Å¯uªÅ¡A²Ê¯uªÅ

prevailing wind,²±¦æ­·

preventive maintenance,¹w¨¾©Êºû­×¡F¹w¨¾©ÊºûÅ@

primary coil,¤@¦¸½u°é

primary current (of a current transformer),¡]¹q¬y¤¬·P¾¹ªº¡^¤@¦¸¹q¬y

primary device,¤@¦¸¸Ë¸m

primary feedback,¥D¤ÏõX

primary force standard machine,¤O°ò­ãÉó

primary standard,°ò­ã¡]¾¹¡^

primary voltage,¤@¦¸¹qÀ£

primary winding,¤@¦¸Â¶²Õ

principal component analysis (PCA),¥D¦¨¤À¤ÀªRªk

principal period of calorimetric test,¶q¼ö¹êÅ窺¥D´Á

principal plane,¥D¥­­±

principal point,¥DÂI

principal stress,¥DÀ³¤O

principle of measurement,´ú¶q­ì²z

printer,¥´¦LÉó¡F¦L¨êÉó

printing current meter,¦L¨ê®ü¬y­p

printing recorder,¥´¦L¦¡°O¿ý»ö

priority,ɬ¥ýÅv¡Fɬ¥ý¯Å

prism mass spectrometer,Ù±Ãè½èÃЭp

prism monochromator,Ù±Ãè³æ¦â»ö

probe,±´ÀY

probe coil,±´ÀY½u°é

probe coil clearance,±´ÀY½u°é¶¡»Ø

probe index,±´ÀY¤J®gÂI

probe ion,±´°wÖäl

probe method,±´°wªk

probe microphone,±´ºÞ¶ÇÁnºÞ

probe rotational scan,Â\°Ê±½¬d

probe to flaw distance,±´ÀY-¯Ê³´¶ZÖÃ

problem oriented language,­±¦V°ÝÃDªº»y¨¥

procedure-oriented language,­±¦V¹Lµ{ªº»y¨¥

process automation,¹Lµ{¦Û°Ê¤Æ

process control,¹Lµ{±±¨î

process control computer,¹Lµ{±±¨î­pºâÉó

process control level,¹Lµ{±±¨î¯Å

process control software,¹Lµ{±±¨î³n¥ó

process control system,¹Lµ{±±¨î¨t²Î

process engineer's console,¹Lµ{¤uµ{®v¾ÞÁa¥x

Process Fieldbus;PROFIBUS¡A¹Lµ{²{³õÁ`½u¡FPROFIBUS²{³õÁ`½u

process gas chromatograph,¬yµ{Éa¬Û¦âÃлö

process I/O,¹Lµ{¿é¤J/¿é¥X¡F¹Lµ{I/O

process input/output channel,¹Lµ{¿é¤J¿é¥X³q¹D

process input/output device,¹Lµ{¿é¤J¿é¥X¸Ë¸m

process mass spectrometer,¬yµ{½èÃЭp

process measurement,¹Lµ{´ú¶q

process model,¹Lµ{¼Ò«¬

process-oriented sequential control,¹Lµ{©w§Ç¶¶§Ç±±¨î

process-oriented simulation,­±¦V¹Lµ{ªº¥é¯u

processibility test,¤uÃÀ©Ê¯à¸ÕÅç

processor,³B²zÉó¡F³B²z¾¹¡F³B²zµ{§Ç

prod magnetizing method,¤ä§ýªk¡F¶ê´Î¹qÌåºÏ¤Æªk

prods,¤ä§ýàDÀY

product specification,²£«~³W­S

product standard,²£«~¼Ð­ã

production budget,¥Í²£¹wºâ

production function,¥Í²£¨ç¼Æ

Profibus-DP (Decentralized Periphery),PROFIBUS-¤À´²«¬¥~³ò³]³ÆÁ`½u

Profibus-FMS (Field Message Specification),PROFIBUS-²{³õ³ø¤å³W­SÁ`½u

Profibus-PA (Process Automation),PROFIBUS-¹Lµ{¦Û°Ê¤ÆÁ`½u

Profile,¦æ³W

profit control,§Q¼í±±¨î

profit forecast,§Q¼í¹w´ú

program,µ{§Ç

program architecture,µ{§ÇÊ^¨tµ²ÌÛ

program-controlled testing machine,µ{§Ç±±¨î¸ÕÅçÉó

program correctness,µ{§Ç¥¿ÚÌ©Ê

program debugging tool,µ{§Ç½Õ¸Õ¤u¨ã

program evaluation and review technique (PERT),­p¦Eµû¼f§Þ³N

program execution time,µ{§Ç°õ¦æ®É¶¡

program file,µ{§Ç¤å¥ó

program file,µ{§Ç¤å¥ó

program library,µ{§Ç®w

program linking,µ{§Ç³s±µ

program mode,µ{§Ç¤è¦¡

program read-in,µ{§ÇŪ¤J

program run,µ{§Ç¹B¦æ

program set station,µ{§Ç³]©w¾Þ§@¾¹

program specification,µ{§Ç³W®æ»¡©ú

program validation,µ{§ÇÚÌ»{

programmable controller,¥i½sµ{§Ç±±¨î¾¹

programmable logic controller (PLC),¥i½sµ{§ÇÅÞ¿è±±¨î¾¹

programmable terminal,¥i½sµ{²×ºÝ

programme control digital logger,µ{±±¼Æ¦r´ú¤«»ö

programmed control,µ{§Ç±±¨î

programmed control system,µ{§Ç±±¨î¨t²Î¡Fµ{±±¨t²Î

programmed flow gas chromatography,µ{§ÇÅܬyÉa¬Û¦âÃЪk

programmed pressure gas chromatography,µ{§ÇÅÜÀ£Éa¬Û¦âÃЪk

programmed temperature gas chromatography,µ{§Ç¤É·ÅÉa¬Û¦âÃЪk

programmer,µ{§Ç¡]³]­p¡^­û

programmer's console,µ{§Ç­û¾ÞÁa¥x

programming,µ{§Ç³]­p

programming flowchart,µ{§Ç³]­p¬yµ{¹Ï

programming support environment,µ{§Ç³]­p¤ä«ùÀô¹Ò

projector,§ë¼vÃè

projector for transferring,§ë¼vÂàø»ö

propeller,¡]Á³¡^±Û¼ß

propeller anemograph,Á³±Û¼ß­·¦V­·³t­p

propeller type current-meter,±Û¼Õ¦¡¬y³t­p

proportional action;P-action,¤ñ¨Ò§@¥Î¡FP-§@¥Î

proportional action coefficient,¤ñ¨Ò§@¥Î¨t¼Æ

proportional band(of a controller),(±±¨î¾¹ªº¡^¤ñ¨Ò±a

proportional bandwidth filter,¤ñ¨Ò±a¼eÂoªi¾¹

proportional control,¤ñ¨Ò±±¨î

proportional controller; P controller,¤ñ¨Ò±±¨î¾¹¡FP±±¨î¾¹

proportional electric actuator,¤ñ¨Ò¦¡¹q°Ê°õ¦æÉóÌÛ

proportional gain,¤ñ¨Ò¼W¯q

proportional limit,¤ñ¨ÒÌå­­

proportional plus derivative action;PD-action,¤ñ¨Ò·L¤À§@¥Î¡FPD-§@¥Î

proportional plus derivative control,¤ñ¨Ò·L¤À±±¨î

proportional plus derivative controller;PD controller,¤ñ¨Ò·L¤À±±¨î¾¹¡FPD±±¨î¾¹

proportional plus integral action;PI-action,¤ñ¨Ò¿n¤À§@¥Î¡FPI-§@¥Î

proportional plus integral control,¤ñ¨Ò¿n¤À±±¨î

proportional plus integral controller;PI controller,¤ñ¨Ò¿n¤À±±¨î¾¹¡FPI±±¨î¾¹

proportional plus integral plus derivative action;PID-action,¤ñ¨Ò¿n¤À·L¤À§@¥Î¡FPID-§@¥Î

proportional plus integral plus derivative control,¤ñ¨Ò¿n¤À·L¤À±±¨î

proportional plus integral plus derivative controller;PID controller,¤ñ¨Ò¿n¤À·L¤À±±¨î¾¹¡FPID±±¨î¾¹

proportionality transmitter,¤ñ­ÈÅܰe¾¹

prospecting potentiometer,±´Äq¹q¦ì­p

protected junction,«OÅ@ºÝ

protective current transformer,«OÅ@¥Î¹q¬y¤¬·P¾¹

protective device,«OÅ@¸Ë¸m

protective tube,«OÅ@ºÞ

protective voltage transformer,«OÅ@¥Î¹qÀ£¤¬·P¾¹

protocol,¨óij

protocol engineering,¨óij¤uµ{

proton(precession) magnetometer,½è¤l±Û¶iºÏ¤O»ö

prototype,­ì«¬

prototype process time,­ì«¬¹Lµ{®É¶¡

prototype variable,­ì«¬Åܶq

prover (ball or piston),¡]²y¦¡©Î¬¡¶ë¦¡¡^®Õ­ã¸Ë¸m

proving [test] rotor,®ÕÅçÂà¤l

pseudocolor density slicer,°²±m¦â±K«×¤À³Î»ö

psychrometer,¤zÀã²yÀã«×­p¡F¤zÀãªí

psychrometric [hygromtric] tables,Àã«×¬dºâªí

psychrometric constant,Àã«×­pºâ±`¼Æ

psychrometric formula,Àã«×¤½¦¡

pull-rod,©Ô§ý

pulsating flow,¯ß°Ê¬y

pulsating flow of mean constant flow-rate,ùÚ©w¥­§¡¬y¶qªº¯ß°Ê¬y

pulse code modulation (PCM),¯ß½X½Õ¨î¡F¯ß½Ä½s½X½Õ¨î

pulse control,¯ß½Ä±±¨î

pulse duration,¯ß½Ä«ùÄò®É¶¡

pulse duration modulation,¯ß½Ä¼e«×½Õ¨î

pulse duration modulation magnetic tape record type strong-motion instrument,¯ß½Ä½Õ¼e¦¡ºÏ±a°O¿ý±j¾_»ö

pulse echo technique,¯ß½Ä¤Ï®gªk

pulse flip angle,¯ß½Ä¦^Âਤ

pulse Fourier transform NMR,¯ß½Ä³Å¥ß¸­ÅÜ´«®ÖºÏ¦@®¶¡]ªk¡^

pulse Fourier transform NMR spectroscope,¯ß½Ä³Å¨½¸­ÅÜ´«®ÖºÏ¦@®¶ªiÃлö

pulse frequency modulation control system,¯ß½Ä½ÕÀW±±¨î¨t²Î

pulse frequency modulation magnetic tape record type strong-motion instrument,¯ß½Ä½ÕÀW¦¡ºÏ±a°O¿ý±j¾_»ö

pulse pileup rejection,¯ß½Ä°ï¿n±Æ°£¾¹

pulse polarograph,¯ß½ÄÌåÃлö

pulse position modulation,¯ß½Ä¦ì¸m½Õ¨î

pulse recurrence frequency,¯ß½Ä­«Î`ÀW²v

pulse repetition frequency,¯ß½Ä­«Î`ÀW²v

pulse transducer [sensor],¯ß·i¶Ç·P¾¹

pluse type airborne electromagnetic instrument,¯ß½Ä¦¡¯èªÅ¹qºÏ»ö

pulse type NMR spectroscope,¯ß½Ä®ÖºÏ¦@®¶ªiÃлö

pulse-width modulation,¯ß½Ä¼e«×½Õ¨î

pulse width modulation control system; PWM control system,¯ß½Ä½Õ¼e±±¨î¨t²Î

pulsed-light ceilometer,¯ß½Ä¥ú§ô¤ª°ª­p

pulsed-light cloud-height indicator,¯ß½Ä¥ú§ô¤ª°ª­p

pulsed optical feedback,¯ß½Ä¥ú¤ÏõX

pump,¬¦

punched card,¬ï¤Õ¥d¤ù

punched tape,¬ï¤Õ±a

Pusey and Jones indentation hardness number,»¯¤óµw«×­È

Pusey and Jones indentation instrument,»¯¤óµw«×­p

pyranograph,Á`¤é®g­p

pyranometer,Á`¤é®gªí

pyrgeometer,¦a²y¿ç®gªí¡F¤jÉa¿ç®gªí

pyrheliometer,ª½±µ¤é®g±j«×ªí¡F¤é®gªí

pyroelectric optical transducer [sensor],¼öÄÀ¹q¦¡¥ú¶Ç·P¾¹

pyroelectric temperature transducer [sensor],¼öÄÀ¹q¦¡·Å«×¶Ç·P¾¹

pyrolysis apparatus,µõ¸Ñ¾¹

pyrolysis gas chromatography,µõ¸ÑÉa¬Û¦âÃЪk

pyrometer lamp,°ª·Å­p¿Oªw

pyrradiometer,¥þ¿ç®gªí

*¤W½g¤å³¹: ¹q¤uµü¶×­^º~¹ï·ÓQ
*¤U½g¤å³¹: ¹q¤uµü¶×­^º~¹ï·ÓO
  ¨ä¥L¬ÛÃö¤å³¹
  • Ãö¤_¤¤°ê±j¨î»{µý¨î«×
  • ¤¤°êÉOªF·ù°ê®a»â¾É¤HÁp¦X«Å¨¥
  • ¤¤°êÉOªF·ù¤Í¦n¦X§@¤j¨Æ°O
  • ¤¤°ê©MªF·ùªº·ü¾F¤Í¦n¦X§@Ãö¨t
  • ¡¡¤¤°êÉOªF·ù°ê®a­º¸£·|±àÁp¦XÁn©ú¡¡(1997¦~)
  • ¤¤°ê¡¡ªF·ù°ª©x½R°Ó
  • ¶V«nÂX¤j¹ïµØªG½­¥X¤f
  • °ê¤ºÄvª§ºG¯P·¿²£¤j¿é²G¶i­xªF·ù
  • ®õ°ê¹ï¿ûÅK¶i¤f«ìÎ`¤Ï¶É¾Pµ|
  • ¶V«n½¼¹A§Üij¬ü¹ï¶V½¼²£«~¹ê¦æ¤Ï¶É¾P
  •   ®üÃö¶i¥X¤f²Î­p¼ÆÕu
  • ¾FÁD¡@­f¡@¨ÈÓi ¶i¥X¤f²Î­p¼ÆÕu/Ãöµ|µ|²v¤Î¬ÛÃö¤å³¹¬d¸ß
  • °¨¨Ó¦è¨È¶i¥X¤f²Î­p¼ÆÕu
  • ¦³¦âª÷Äݶi¥X¤f²Î­p¼ÆÕu
  • «Oµ|°Ï­ÜÀxÂà¤f³fª«¥X¤f°Ó«~²Î­p¼ÆÕu
  • Érªi¸gÀÙ§Þ³N¶}µo°Ï¶i¥X¤f²Î­p¼ÆÕu
  • ¶À®H®üÃö¶i¥X¤f²Î­p¼ÆÕu
  • ·Å¦{¥«¶i¥X¤f²Î­p¼ÆÕu
  • ´ª«¨îªA¸Ë¥X¤f®üÃö²Î­p¼ÆÕu
  • ¹q¦À¶i¤f®üÃö²Î­p¼ÆÕu
  • ¥ú¾Ç¡¡ÂåÀøµ¥»ö¾¹¡FÄÁªí¡F¼Ö¾¹¶i¥X¤f²Î­p¼ÆÕu
  •   Ãì±µ¾É¯è
    §K¶O¤J¦í¤¤°ê¶i¥X¤f¥ø·~¶À­¶
    ¤Æ¤u¦æ·~¶i¥X¤f¤Æ¤u°Ó«~®üÃö½s½XÂkÃþ
    2007¦~³Ì·s®üÃöÃöµ|µ|²vµ|«h